Powergrid Tolerances

Panel Tolerances (as Manufactured)
Panel Size-Molded +/-1/8"(+/-3mm) (width,length & diagonal)
Panel Size-Pultruded +/-1/4"(+/-6mm) (width,length & diagonal)
Grating Depth +/-1/16"(+/-1.5mm)
Panel Flatness(Warp) +/-1/32"(+/-0.8mm)per ft. (length direction)
  +/-1/16"(+/-1.5mm)per ft. (Width direction)
 
Cutting Tolerances(as Fabricated)
Rectangular Cuts +0", -1/4" (+0, -6.4mm)
Straight Cuts +0", -1/4" (+0, -6.4mm)
Circular Cuts +0", -3/8" (+0, -9.5mm)
 
Grating Clearances
To Side of Trench 1/4" (6.4mm)
To Wall 1/2" (13mm)
Between Panels 0" to 1/4" (0 to 6.4mm)
   
Minimum Support Width 1 1/2" (38mm) minimum(nominal)
   
Attachment 2 Hold-downs at Each Suppport
 
Banding
Plate 1/8"(3mm) min. attached with bolts or leg screws
Straight Banding - attachments spaced 12"(30.5mm) centers
Curved Banding - attachments spaced 9"(23mm) Max. (dependant on radius)